Over 99% dust containment

Floor to ceiling; any height and length

No mess, quick/easy installation

Antibacterial
materials

Fire rated materials on request

Takes up minimal
floor space

Flexiscreen

Flexiscreens are temporary floor-to-ceiling dust screens used to contain dust during construction, flooring, installation and extension works within live manufacturing, production and warehouse environments. Used for both internal and external applications, this versatile temporary screening system is a robust alternative to traditional scaffold sheeting methods.

Flexiscreens are superior temporary dust screens which are fast, easy and clean to install and suitable for both short and long term projects. During phased works they can be moved, reconfigured and extended if required.

Designed and installed to suit any height and width of building (subject to survey), its rapid installation process means disruption in any environment is minimised to maintain existing production schedules.

The unique v-overlap system and tight seal around ducts, pipes, steel work and at ceiling level ensures that Flexiscreen offers an over 99% dust tight seal.

The suspended panel-based system requires no additional supporting frame work as it is suspended from the existing building structure, and can be installed on an angle to fit the profile of the building and accommodate tight gaps. Taking up minimal floor space, it can easily be installed in tight spaces and around existing equipment in manufacturing and production environments.

Choose from a range of materials and access options to suit the needs of the project (i.e antifungal materials or fire rated) or environment. Wind load calculations and designs are available for external walls or high wind load areas.

View our full range of temporary and permanent screening systems for a variety of purposes.

  • Screen off production line installations to prevent cross contamination in a live manufacturing facility – including in food manufacturing
  • Dust containment during flooring and drainage works
  • Create an enclosure around areas where the roof needs to be removed, for temperature and contamination prevention
  • Internal relocatable screen to allow for phased openings in large buildings, typically large warehouses
  • Manage temperature and draughts during floor curing
  • Temporary external walls for weather protection during extension and construction projects
Material composite:Main product is polyester reinforced fire-retardant fabric with PVC coatings. We also supply a non-combustible woven glass fabric with PU coating (*range of base fabric and coatings depending on your requirement)
Material weight:between 175gsm-840gsm
Tensile strength:between 800N-3400N / 50mm
Tear strength:between 250N-850N
Material fire rating examples:BS 5867:2008 Part 2 Type A & B, Warrington Certifire TS62 & TS63, En13501-1 A2s1do, EN13501-1 Bs2d0, EN13501-1 Cs2d0 (*subject to material specification, all fire ratings supplied at quote stage)
Operating temperature:between -40 / +70 degree centigrade – dependent on fabric type
Sound reduction:between 11dB – 13dB
Thermal resistance:between 5.68 – 5.40 W/m2K

What are your lead times?
Due to the bespoke nature of our products lead times vary. However, because we manage our own in-house contracts team, we are able to provide you with an accurate and up to date lead time at point of enquiry.

How do I establish if my building structure can support your system?
Westgate provide full design support and system specific calculations that can be used to establish this.

Where are your products manufactured?
Our products are manufactured and quality controlled in the UK.

How do I overcome wind load requirements?
We evaluate site specific wind load requirements as part of the design process. Where high wind loads are an issue additional features (e.g. wind load straps) can be built in to the design.

Does the system have to be battened to the floor?
No, we can provide a number of fixing options for your building screen solution. Please contact us for full details.

Place an enquiry

Choose your estimated project start date:
How many individual runs of wall are there?
Please detail the estimated maximum W x H for each run (eg. 10m x 10m):
Do you require access options?
Please upload any drawings or images you have to help us assess your enquiry. Image size must be less than 2MB. Please upload in JPG or PNG format only.
We will use your personal data to process your request. We would also like to send you information about our products, projects, industry insights and company news. If you would prefer not to hear from us, please tick the relevant boxes below:
You can change your mind at any time. To learn more about how we handle your data, please refer to our privacy policy. Please note you may still receive customer service based communications including surveys or updates about ongoing requests you have with Westgate Global.

Request a call from one of our experts

We’d be happy to assist and discuss your requirements with you. Our aim is to find the right cost effective solution for your needs from our range of partitioning and hoarding systems.

Contact time

Or call us now to discuss how we can help…

Open Monday to Friday, 7.30am to 4.30pm.

Tel: +44 (0)1785 242181